Binder FED 260 Avantgarde line 259L Heating Oven features advanced timing functions and the fan, temperature and convection conditions are easily controlled. They have been designed with excellent temporal and spatial temperature accuracy, and up to 30% lower energy consumption compared to conventional units on the market.
Benefits
259L Capacity
Temperature range: +10 ℃ above ambient temperature to +300 ℃
Up to 30% lower energy consumption compared to conventional units on the market
Excellent temporal and spatial temperature accuracy
High-temperature accuracy thanks to APT.line™ technology
Adjustable fan speed
Controller with LCD display and enhanced time functions
Electromechanical control of the exhaust air flap
2 chrome-plated racks
Units up to 115 litres are stackable
Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
Ergonomic handle design
Ethernet interface
USB port for recording data
Technical Specifications
Designation
FED260-230V*
Option model
Standard
Order number
9010-0299
Data
Serie
FED
Performance Data Temperature
Heating-up time to 150 ℃ [min]
19
Recovery time after 30 seconds door open at 150 ℃ [min]
5
Temperature fluctuation at 150 ℃ [± K]
0.4
Temperature range +10 ℃ above ambient temperature to [℃]
300
Temperature variation at 150 ℃ [± K]
1.6
Air change data
Air change (approx.) at 100 ℃ [x/h]
9
Electrical data
Nominal power [kW]
2.3
Phase (Nominal voltage)
1~
Power frequency [Hz]
50/60
Rated Voltage [V]
230
Unit fuse [A]
12.5
Doors
Unit doors
1
Housing dimensions, not incl. fittings and connections
Depth net [mm]
760
Height net [mm]
940
Width net [mm]
810
Internal Dimensions
Depth [mm]
515
Height [mm]
780
Width [mm]
650
Measures
Interior volume [L]
259
Load per rack [kg]
40
Net weight of the unit (empty) [kg]
84
Permitted load [kg]
270
Wall clearance back [mm]
160
Wall clearance sidewise [mm]
100
Environment-specific data
Energy consumption at 150 ℃ [Wh/h]
410
Sound-pressure level [dB(A)]
43
Fixtures
Number of shelves (std./max.)
2/8
*All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 ℃ ±3 ℃ and a power supply voltage fluctuation of ±10 %. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
Our standard delivery is 3-5 working days (where products are available) Monday to Friday, excluding public holidays when you order by 2pm. Details of our returns and cancellation policy can be found in our Returns Policy & Section 11 of our Terms and Conditions. For more information please contact us on 01924 444 577 or Email Us.