For general use
Quantity

The minimum purchase order quantity for the product is 10.

  • Slide Format: Large Pushfit
  • Agar (Side 1): Plate Count
  • Detection (Side 1): Total Count
  • Agar (Side 2): Plate Count
  • Detection (Side 2): Total Count
  • Shelf Life: 9 Months
  • Storage Temp.: 8 - 15 C
  • Incubation: 35 C - 24 - 48 Hrs
  • 10 Dipslides per box
  • Minimum Order Quantity: 10 boxes
Go to Product Description

ASK A QUESTION

Please fill in the form below to ask a question about this product:

  100% Secure Shopping

100% Secure Shopping & Payment Gateway

  Express Delivery

We aim to ship all stocked items within 1-3 working days.

  Hassle Free Returns

Not 100% happy with your order? find out more about our returns policy.

Gem Scientific plate count agar for general use.

  • Slide Format: Large Pushfit
  • Agar (Side 1): Plate Count
  • Detection (Side 1): Total Count
  • Agar (Side 2): Plate Count
  • Detection (Side 2): Total Count
  • Shelf Life: 9 Months
  • Storage Temp.: 8 - 15 C
  • Incubation: 35 C - 24 - 48 Hrs
  • 10 Dipslides per box
  • Minimum Order Quantity: 10 boxes

The media that Gem Scientific use is designed to not only provide you with the most accurate results but visually distinctive dependent on the product type and the level of bacteria found at the original testing location

Within each box of Gem Scientific dip slides is a handy comparison chart to demonstrate what level of contamination the tested area has. This is measured by the coverage of the media by the bacteria recovered from the sample or area tested. Regular testing is recommended to ensure your regimes are being maintained and bacteria levels are as low as possible.

Storage

Store in a cool dry place (Optimum 8-15oC) and use before the expiry date on the box. Do not use slides if there is any sign of growth before opening. Slides remain usable while the agar is smooth and attached to the slide. A small amount of water may collect at the bottom of the tube. This is condensate from the agar and does not affect performance, provided the agar still fills the tray.

Disposal

Used slides should be incinerated, autoclaved or soaked in disinfectant for several hours before disposal.

DIM-PC2

Our standard delivery is 3-5 working days (where products are available) Monday to Friday, excluding public holidays when you order by 2pm. Details of our returns and cancellation policy can be found in our Returns Policy & Section 11 of our Terms and Conditions. For more information please contact us on 01924 444 577 or Email Us.

16 other products in the same category:

Availability: Out of stock

The body and cap of our Detectamark Permanent Marker are moulded from high-density polyethylene, containing a non-toxic metal detectable additive. This compound can be detected by correctly calibrated in-line metal detection systems. The Detectamark features Sureflow ink, meaning the pen will continue to write for several days, even if the cap is left off. This alcohol-based ink will permanently mark most surfaces, including wood, plastic, glass, concrete, and clean or printed metals.

Available in blue, black, red, and green ink in bullet nib with a multi coloured pack also available.

Blue and black ink are available in the fine tip nib.

Bile Esculin Azide Agar

£1,815.87 vat excl.

£2,179.04 vat Inc.

Availability: Out of stock
Bile Esculin Azide Agar is used for the selective isolation and differentiation of group D streptococci in a laboratory setting. Bile Esculin Azide Agar is not intended for use in the diagnosis of disease or other conditions in humans. Bile Esculin Azide Agar is a modification of the medium reported by Isenberg and Isenberg, Goldberg, and Sampson. This formula modifies Bile Esculin Agar by adding sodium azide and reducing the concentration of bile. The revised medium is more selective, but still provides rapid growth and efficient recovery of group D streptococci. Molecular taxonomic studies of the genus Streptococcus have placed enterococci, previously described group D streptococci, in the genus Enterococcus. The ability to hydrolyze esculin in the presence of bile is a characteristic of enterococci and group D streptococci. Swan compared the use of an esculin medium containing 40% bile salts with the Lancefield serological method of grouping and reported that a positive reaction on the bile esculin medium correlated with a serological group D precipitin reaction. Facklam and Moody found that the bile esculin test provided a reliable means of identifying group D streptococci and differentiating them from non-group D streptococci. Bile Esculin Azide Agar selected for S. bovis, displayed earlier distinctive reactions, and eliminated the requirement for special incubation temperatures.

Palcam Agar Base

£919.79 vat excl.

£1,103.75 vat Inc.

Availability: Out of stock
Palcam Agar Base is used with supplements as a selective and differential medium for the detection and isolation of Listeria monocytogenes from food and environmental samples. Palcam Agar Base is not intended for use in the diagnosis of disease or other conditions in humans. Palcam Agar was developed by Van Netten et al in 1989 as an improved selective differential medium for the isolation of Listeria monocytogenes from food and environmental specimens. Improved selectivity is achieved by the combination of antibiotic supplements and microaerobic incubation. The double indicator system of esculin hydrolysis and mannitol fermentation aids differentiation of Listeria spp from enterococci and staphylococci which can be confused with Listeria spp on other types of culture media. Palcam Agar is listed within Annex E of ISO 11290-1:2017 as a suitable second selective agar.

Reagent Reservoir 25mL Sterile Bulk Wrap Polystyrene

£48.70 vat excl.

£58.44 vat Inc.

Availability: 10 In Stock
  • A full range of volumes and styles available to accommodate required volume of reagents and reduce waste
  • “V" shaped well design allows maximum reagent recovery
  • Easy to read graduation markings located on the top edge with a fill line on inner walls to indicate volume levels
  • Drip free pour-off spouts at every corner for spill free pouring
  • Manufactured in a clean room with sterile versions certified as RNase/DNase and pyrogen free
  • Designed for multi-channel pipettes and accommodates most common brands
  • A wide base ensures stability and tiered wall design prevents deformation when handling and reduces the chance of spills
  • A unique nesting design allows easy separation that reduces the chance of warped or damaged product
  • Free of animal products
  • Quality certificate available
  • Easy tear packaging makes handling quick and efficient
  • Lot numbers indicated on sterile versions
  • Patent Pending
  • Pack of 100

SenTix® Micro 900-P IDS pH Micro Electrode

£428.00 vat excl.

£513.60 vat Inc.

Availability: 20 In Stock
  • pH measuring range 0 to 14
  • Safely measured values due to signal processing in the sensor
  • Easy electrode replacement thanks to calibration data stored inside sensor
  • Sensor quality monitoring by QSC function
  • IDS pH microelectrode
  • For measurement of small volumes and in small vessels
  • Diameter 5mm
  • QSC function
  • Integrated temperature sensor
  • Memory for 10 calibrations

EC Broth

£774.99 vat excl.

£929.99 vat Inc.

Availability: Out of stock
EC Broth is used for the detection of coliform bacteria at 37°C and Escherichia coli at 44.5°C. EC Broth is not intended for use in the diagnosis of disease or other conditions in humans. EC Broth ( Escherichia coli Broth) is a selective enrichment broth designed for the isolation of coliforms, including E. coli, from water and food samples. It was the recommended medium of the American Public Health Association (APHA) and the AOAC. EC Broth is made selective for coliforms by the inclusion of Bile Salts in the dehydrated medium. The selective nature of this medium ensures that the growth of non-coliform bacteria is minimized. The medium is buffered by the addition of potassium phosphates and osmotically balanced by sodium chloride. The medium is used at 37°C for coliform organisms and 44.5°C is recommended for the isolation E. coli.