IDEXX

Colilert (Coliform and E.coli Detection)

Pack Size : 100
for Sample Size : 100ml
Quantity

  • Ease of use simplifies training.
  • Unit-dosed packaging eliminates media preparation.
  • No repeat testing due to clogged filters or heterotrophic interference.
  • Quality Control (QC) procedure can be done in 15 minutes.
Go to Product Description

ASK A QUESTION

Please fill in the form below to ask a question about this product:

  100% Secure Shopping

100% Secure Shopping & Payment Gateway

  Express Delivery

We aim to ship all orders within 1-3 working days.

  Hassle Free Returns

Not 100% happy with your order? find out more about our returns policy.

Related Products

Transform 100 Nitrile...
Availability: 5 In Stock
  • Available sizes: small, medium or large
  • Pack of 100 gloves
  • 3.2mil Powder-Free Nitrile
  • Non-Sterile
  • Beaded cuff
  • Ambidextrous
  • Latex Free
  • AQL 1.5

IDEXX Colilert simultaneously detects or quantifies both total coliforms and Escherichia coli (E.coli) in just 24 hours. Preparation of the test takes less than one minute and removes the need for time-consuming confirmations and colony counting.

The IDEXX Colilert Test is used around the world for the detection of coliforms and E.coli. Colilert uses the patented Defined Substrate Technology (DST) to simultaneously detect total coliforms and E.coli. This approach is different from traditional media, which provide a nutrient-rich environment that supports the growth of both target organisms and non-targets.

When non-targets grow and mimic target organisms, false positives occur. Growth of non-targets can also suppress target organisms and give false negatives in traditional media. To suppress non-targets, traditional media often include high levels of salts, detergents or other selective agents that may inadvertently suppress target organisms and give further false negatives.

Easy

  • Ease of use simplifies training.
  • Unit-dosed packaging eliminates media preparation.
  • No repeat testing due to clogged filters or heterotrophic interference.
  • Quality Control (QC) procedure can be done in 15 minutes.

Rapid

  • Less than 1 minute of hands-on time.
  • Detects coliforms and E.coli simultaneously in 24 hours or less.
  • No confirmations needed.
  • No glassware cleaning or colony counting.

Accurate

  • Identifies E.coli specifically, eliminating unnecessary public notification due to non-target organisms.
  • Suppresses up to 2 million heterotrophs per 100 ml and 5 million per 250 ml.
  • Eliminates the subjective interpretation found in traditional methods.
  • Detects a single viable coliform or E.coli per sample.

Economical

  • Minimises evening and weekend work.
  • Up to 12-month shelf life at room temperature
  • Available sample size: 100 or 250ml
  • Available pack size: 20 (only for 100ml), 100 or 200

Colilert can be used as a presence/absence test or results can be quantified using the Idexx Quanti-Tray and an MPN table. A negative sample appears clear while a positive sample for coliforms is yellow. A positive E.coli sample will be yellow and will fluoresce under ultraviolet light.

How it works

The Colilert test uses proprietary Defined Substrate Technology (DST) to simultaneously detect total coliforms and E.coli. Two nutrient-indicators, ONPG and MUG, are the major sources of carbon in Colilert and can be metabolised by the coliform enzyme ß-galactosidase and the E.coli enzyme ß-glucuronidase, respectively.

As coliforms grow in the Colilert Test, they use ß-galactosidase to metabolise ONPG and change it from colourless to yellow.

E.coli use ß-glucuronidase to metabolise MUG and create fluorescence. Since most non-coliforms do not have these enzymes, they are unable to grow and interfere. The few non-coliforms that do have these enzymes are selectively suppressed by the Colilert Test's specifically formulated matrix.

This approach is different from traditional media, which provide a nutrient-rich environment that supports the growth of both target organisms and nontargets. When nontargets grow and mimic target organisms, false positives occur. Growth of nontargets can also suppress target organisms and give false negatives in traditional media. To suppress nontargets, traditional media often include high levels of salts, detergents, or other selective agents that may inadvertently suppress target organisms and give further false negatives.

Only IDEXX reagents have been validated and approved for use with Quanti-Tray and Quanti-Tray/2000.

IDX-98-27163-00

Data sheet

Industries
Water Analysis

Our standard delivery is 3-5 working days (where products are available) Monday to Friday, excluding public holidays when you order by 2pm. Details of our returns and cancellation policy can be found in our Returns Policy & Section 11 of our Terms and Conditions. For more information please contact us on 01924 444 577 or Email Us.

8 other products in the same category:

Colilert-18 (Coliform and...

Colilert-18 (Coliform and e.Coli Detection)

£866.99 vat excl.

£1,040.39 vat Inc.

Availability: 20 In Stock
  • Detects coliforms and E. coli simultaneously in 18 hours.
  • Unit-dosed packaging eliminates media preparation.
  • No repeat testing due to clogged filters or heterotrophic interference.
  • Quality Control (QC) procedure can be done in 15 minutes.
  • 100ml samples, 200 test pack
Industrial Legionella Field...

Industrial Legionella Field Test Kit

£324.00 vat excl.

£388.80 vat Inc.

Availability: 5 In Stock
  • Highly sensitive test
  • Sample Type: Water sample obtained by the connection to pipe fitting
  • Sample Volume: 250 ml
  • Sensitivity: 100 CFU/L Legionella pneumophila sg1
  • Pack Size: 5 Tests
  • Shelf Life: 18 months from the date of manufacture
  • Kit includes pre-filled syringes containing recovery buffer. No need to measure or dilute solutions
  • Provides straightforward results, on-site, within 25√¢Äì35 minutes
  • Regular use increases confidence in Legionella controls
  • Smartphone App reader provides an independent record of results
Vessels for Water Testing

Vessels for Water Testing

£144.13 vat excl.

£172.96 vat Inc.

Availability: 49 In Stock
  • Tear off or Shrink Banded seal
  • 120ml or 290ml Capacity
  • Available with or without sodium thiosulphate
Quanti-Tray System
  • Provides easy, rapid, and accurate bacterial counts.
  • Detects down to one organism per 100 mL.
  • Quanti-Tray and Quanti-Tray/2000 are used when quantifying coliforms, E. coli, enterococci and Pseudomonas aeruginosa.
  • The Quanti-Tray System delivers semiautomated quantification methods based on the Most Probable Number (MPN) model.
Single Legionella Field Test

Single Legionella Field Test

£65.94 vat excl.

£79.13 vat Inc.

Availability: 5 In Stock
  • Highly Sensitive test
  • Sample Type: Water collected from any source
  • Sample Volume: 250 ml
  • Sensitivity: 100CFU/L Legionella pneumophila SG1
  • Pack Size: 1
  • Shelf Life: 18 months from the date of manufacture
  • No need to measure or dilute solutions.
  • Provides straightforward results, on-site, within 25-35 minutes.
  • Regular use increases confidence in Legionella controls.
  • Smartphone App reader provides an independent record of results.
Enterolert-DW (Enterococci...
Availability: 49 In Stock
  • Ready-to-use media.
  • Simple procedure.
  • Most Probable Number (MPN) enumeration.
  • Unit-dosed packaging eliminates media preparation.
  • Reagent contains no toxic compounds.
Swab Legionella Field Test Kit

Swab Legionella Field Test Kit

£294.00 vat excl.

£352.80 vat Inc.

Availability: 4 In Stock
  • Recommended for testing surfaces of:
  • - Water tanks and cooling towers
  • - Showerheads and sinks
  • - Air conditioning units, misters, sprinklers, humidifiers, spa pools and others.
  • Sample Type: surface areas
  • Sample Area: 10 cm
  • Sensitivity: 200 CFU Legionella pneumophila SG1 per swabbed area
  • Pack Size: 5 Tests
  • Simple to use, no interpretation is required.
  • No need to measure or dilute solutions.
  • Provides straightforward results, on-site, within 25√¢Äì35 minutes.
  • Regular use increases confidence in Legionella controls.
  • Smartphone App reader provides an independent record of results.
Pseudalert (Pseudomonas...
Availability: 50 In Stock
  • Blue fluorescence of wells or vessel indicates a positive result.
  • Same familiar platform as the Colilert® test:
  • Ready-to-use reagents, no media preparation.
  • Convenient unit-dosed packaging.
  • No toxic compounds.
  • Use with Quanti-Tray® for most probable number (MPN) enumeration.

This website uses cookies to ensure you get the best experience on our website.