The Funke Gerber LactoFlash is an accurate, reliable instrument for rapid analysis of the main constituents of milk. It directly measures Fat and S.N.F. (Solid Non Fat) and then calculates Density, Protein, Lactose and Freezing Point.
The Funke Gerber LactoFlash is an accurate, reliable instrument for rapid analysis of the main constituents of milk. It directly measures Fat and S.N.F. (Solid Non Fat) and then calculates Density, Protein, Lactose and Freezing Point.
Countless installations in institutes and laboratories all over the world attest to the outstanding quality, reliability and accuracy of this chemical analysis device.The following parameters can be determined quickly and reliably with just one measurement:
Parameter
Resolution
Reproducibility(r)
Measuring Range
Fat
0.01%
0.02% in 0 ... 5% range 0.2 % in 5 ... 30 % range
0 ... 30%
SNF
0.01%
0.04%
0 ...15%
Further parameters are determined based on calculational algorithms:
Parameter
Resolution
Reproducibility(r)
Measuring Range
Density
0.0001
0.001
no limit
Protein
0.01%
0.03%
no limit / calculated value
Lactose
0.01%
0.02%
no limit / calculated value
Gpp
0.001oC
0.002oC
no limit / calculated value
Specification
Technical Specification
Sample capacity:
up to 120/h
Sample volume:
from 12 ml to 20 ml
Interfaces:
1 x parallel, 1 x serial (RS 232 / 9.600 baud), USB 6 volt electrical power supply for thermal printer
Our standard delivery is 3-5 working days (where products are available) Monday to Friday, excluding public holidays when you order by 2pm. Details of our returns and cancellation policy can be found in our Returns Policy & Section 11 of our Terms and Conditions. For more information please contact us on 01924 444 577 or Email Us.
Triple layer for maximum robustness and durability
Unplasticised polyvinylchloride (u-PVC) or polypropylene (PP) internal surfaces is used due to its ability to withstand reaction from strong and corrosive acids
Sash Angled Front with 5° slope minimizes glares and reflections and allows users to work further into the hood without strain
Polycarbonate sash is used as glass is easily etched by hydrofluoric acid.
Isocide™ Antimicrobial Powder Coating eliminates 99.9% of surface bacteria within 24 hours of exposure
Hygiena's ALP Positive Control Kit includes 5 vials of freeze-dried 350 mU/L Alkaline Phosphatase. Kits are used as a reference to the regulatory ALP limit and for ongoing quality control testing.
Temperature range ambient +5ºC to 130ºC, with rapid heat-up time
Stability: ±0.1ºC
Uniformity: ±0.1ºC
Digital temperature control for optimal precision
Range of convenient features including alarms, single and dual point calibration, programmed start/stop, ‘offset' for known sample temperature variation and choice of external or internal probes
Includes block removal tool for easy and safe removal of blocks.
Temperature range ambient +5ºC to 130ºC, with rapid heat-up time
Stability: ±0.1ºC
Uniformity: ±0.1ºC
Digital temperature control for optimal precision
Range of convenient features including alarms, single and dual point calibration, programmed start/stop, ‘offset' for known sample temperature variation and choice of external or internal probes
Includes block removal tool for easy and safe removal of blocks.